We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
LGC Clinical Diagnostics

Download Mobile App




Assay for Risk of Kidney-Allograft Rejection Receives CE Marking Approval

By LabMedica International staff writers
Posted on 18 Nov 2013
European CE marking approval was recently granted for a sensitive, solid-phase assay for the characterization of donor-specific antibodies that distinguish complement binding antibodies from non-complement binding antibodies.

Assessment of the complement-binding capacity of donor-specific anti-HLA antibodies is useful in identifying patients at high risk for kidney-allograft loss. More...
The One Lambda Inc. (Canoga Park, CA, USA) C1qScreen assay was designed to make this task easier.

C1qScreen consists of two reagents, C1q and PE (phycoerythrin)-conjugated anti-C1q. The complement component (C1q) bound by the antigen-antibody complex is detected with an R-phycoerythrin (PE) labeled anti-C1q antibody. Fluorescence intensity is measured using the Luminex (Austin, TX, USA)-based LABScan 100 flow analyzer, which measures the relative amount of antibody bound to the sample.

The Luminex 100/200 System is a flexible analyzer based on the principles of flow cytometry. The system enables simultaneously measurement of up to 100 analytes in a single microplate well, using very small sample volumes. The system delivers fast and cost-effective bioassay results on many assay formats including nucleic acid assays, receptor-ligand assays, immunoassays, and enzymatic assays.

A team of French investigators used the C1qScreen/Luminex system to screen 1016 patients who had received kidney allografts at two transplantation centers in Paris between January 1, 2005, and January 1, 2011, for the presence of circulating donor-specific anti-HLA antibodies and their complement-binding capacity. Graft injury phenotype and the time to kidney-allograft loss were assessed.

Results obtained during the study revealed that patients with complement-binding donor-specific anti-HLA antibodies after transplantation had the lowest five-year rate of graft survival (54%), as compared with patients with noncomplement-binding donor-specific anti-HLA antibodies (93%) and patients without donor-specific anti-HLA antibodies (94%). Thus, the presence of complement-binding, donor-specific anti-HLA antibodies following transplantation more than quadrupled a patient's risk of graft loss. These antibodies were also associated with higher rates of antibody-mediated rejection with more severe graft injury.

“Introducing the C1qScreen assay to the European market is another milestone in One Lambda Inc.'s nearly 30-year history of transplant diagnostic leadership,” said Jar-how Lee, senior vice president of research and development at One Lambda Inc. “A wealth of data from clinical research in the United States, including the recent study cited in the New England Journal of Medicine, documents the promise of this new assay within the transplant field, and we are pleased to make it more broadly available to transplant centers worldwide.”

The French study was published in the September 26, 2013, issue of the New England Journal of Medicine.

Related Links:

One Lambda Inc.
Luminex




Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Verification Panels for Assay Development & QC
Seroconversion Panels
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
Gold Member
Nasopharyngeal Applicator
CalgiSwab 5.5" Sterile Mini-tip Calcium Alginate Nasopharyngeal Swab w/Aluminum HDLE
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Clinical Chemistry

view channel
Image: QIP-MS could predict and detect myeloma relapse earlier compared to currently used techniques (Photo courtesy of Adobe Stock)

Mass Spectrometry-Based Monitoring Technique to Predict and Identify Early Myeloma Relapse

Myeloma, a type of cancer that affects the bone marrow, is currently incurable, though many patients can live for over 10 years after diagnosis. However, around 1 in 5 individuals with myeloma have a high-risk... Read more

Immunology

view channel
Image: The cancer stem cell test can accurately choose more effective treatments (Photo courtesy of University of Cincinnati)

Stem Cell Test Predicts Treatment Outcome for Patients with Platinum-Resistant Ovarian Cancer

Epithelial ovarian cancer frequently responds to chemotherapy initially, but eventually, the tumor develops resistance to the therapy, leading to regrowth. This resistance is partially due to the activation... Read more

Industry

view channel
Image: The collaboration aims to leverage Oxford Nanopore\'s sequencing platform and Cepheid\'s GeneXpert system to advance the field of sequencing for infectious diseases (Photo courtesy of Cepheid)

Cepheid and Oxford Nanopore Technologies Partner on Advancing Automated Sequencing-Based Solutions

Cepheid (Sunnyvale, CA, USA), a leading molecular diagnostics company, and Oxford Nanopore Technologies (Oxford, UK), the company behind a new generation of sequencing-based molecular analysis technologies,... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.