New PCR Assay Rapidly Diagnoses Myotonic Dystrophy Gene Targets

By LabMedica International staff writers
Posted on 01 Mar 2015
In a proof-of-principle study, scientists have developed a conventional-PCR diagnostic test that specifically identifies myotonic dystrophy type 1 (DM1) gene targets from whole blood samples in 15 minutes, obviating the need for prior DNA purification or concentration.

Many PCR-based diagnostics are still considered time- and labor-intensive due to disparate purification, amplification, and detection steps. More...
Advancements in PCR enzymes and buffer chemistry have increased inhibitor tolerance, facilitating PCR directly from crude samples. However, direct PCR protocols have also traditionally employed thermal cyclers with slow ramp-rates and conservative hold-times. The objective of the study was to reduce sample preparation and assay time for a PCR-based genetic test by pairing an inhibitor-resistant enzyme mix with a rapid thermal cycler for direct analysis of whole blood samples.

Scientists from Streck, Inc. (Omaha, NE, USA) improved a genetic screening assay of DM1, a triple-repeat genetic disorder and the most common adult form of muscular dystrophy, through adaptation of a conventional PCR by using Streck’s “PhilisaW Thermal Cycler” and New England Biolabs’ inhibitor-resistant “NEB NextW High-Fidelity 2X PCR Master Mix.” Template sample was 10% whole blood. For detection agarose gel electrophoresis or an Agilent 2100 Bioanalyzer was use. As a reference assay, Gene Link’s “Myotonic Dystrophy Genemer Kit” was used per the kit-specific PCR protocol.

PCR amplification of the DM1 short tandem repeats was completed in 15 minutes using 30 cycles, including in situ hot-start/cell lysis. Out of the 40 donors screened, 23 (57.5%) were identified as DM1 negative. These results were 100% concordant with results using the reference kit.

The outcome is a simple exclusionary screening assay for DM1, independent of up-front sample prep, with significant improvement in time-to-results. This approach could also be applied to adapt other conventional PCR tests where genomic DNA is targeted for analysis.

The paper, by Connelly C et al., was published in the December 2014 issue of the journal BMC Medical Genetics.

Related Links:

Streck



Platinum Member
ADAMTS-13 Protease Activity Test
ATS-13 Activity Assay
Verification Panels for Assay Development & QC
Seroconversion Panels
POCT Fluorescent Immunoassay Analyzer
FIA Go
Gold Member
hCG Whole Blood Pregnancy Test
VEDALAB hCG-CHECK-1
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Clinical Chemistry

view channel
Image: QIP-MS could predict and detect myeloma relapse earlier compared to currently used techniques (Photo courtesy of Adobe Stock)

Mass Spectrometry-Based Monitoring Technique to Predict and Identify Early Myeloma Relapse

Myeloma, a type of cancer that affects the bone marrow, is currently incurable, though many patients can live for over 10 years after diagnosis. However, around 1 in 5 individuals with myeloma have a high-risk... Read more

Immunology

view channel
Image: The cancer stem cell test can accurately choose more effective treatments (Photo courtesy of University of Cincinnati)

Stem Cell Test Predicts Treatment Outcome for Patients with Platinum-Resistant Ovarian Cancer

Epithelial ovarian cancer frequently responds to chemotherapy initially, but eventually, the tumor develops resistance to the therapy, leading to regrowth. This resistance is partially due to the activation... Read more

Technology

view channel
Image: Ziyang Wang and Shengxi Huang have developed a tool that enables precise insights into viral proteins and brain disease markers (Photo courtesy of Jeff Fitlow/Rice University)

Light Signature Algorithm to Enable Faster and More Precise Medical Diagnoses

Every material or molecule interacts with light in a unique way, creating a distinct pattern, much like a fingerprint. Optical spectroscopy, which involves shining a laser on a material and observing how... Read more

Industry

view channel
Image: The collaboration aims to leverage Oxford Nanopore\'s sequencing platform and Cepheid\'s GeneXpert system to advance the field of sequencing for infectious diseases (Photo courtesy of Cepheid)

Cepheid and Oxford Nanopore Technologies Partner on Advancing Automated Sequencing-Based Solutions

Cepheid (Sunnyvale, CA, USA), a leading molecular diagnostics company, and Oxford Nanopore Technologies (Oxford, UK), the company behind a new generation of sequencing-based molecular analysis technologies,... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.