We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
LGC Clinical Diagnostics

Access Bio Inc

Access Bio is dedicated to the prevention and early diagnosis of infectious diseases through research, development, a... read more Featured Products: More products

Download Mobile App




Malaria Rapid Test Evaluated in Low Transmission Area

By LabMedica International staff writers
Posted on 23 Aug 2017
Light microscopy detecting human malarial parasites in Giemsa-stained thick and thin blood films still remains the gold standard for malaria diagnosis. More...
In many peripheral health centers of endemic countries, microscopy is not available due to limited resources or lack of expertise.

Malaria rapid diagnostic tests (RDTs), based on immunochromatographic parasite antigen detection, are of great value in endemic regions. However, it remains unclear whether RDTs are useful in field conditions in low transmission areas since their reliability is limited by the lack of detection of low-density parasitemia.

Scientists at Cheikh Anta Diop University (Dakar, Senegal) enrolled 215 patients suspected of malaria in two peri-urban area of Dakar. Blood samples were collected for RDT and microscopy, and a filter paper collected for polymerase chain reaction (PCR). Inclusion criterion for this study was individuals with fever and suspicion of malaria and without clinical sign of severe malaria.

The team made both thick and thin films were made in the same slide which were stained and examined. Finger prick blood sample were tested for malaria parasites using CareStart Malaria HRP2/pLDH Combo Test in the field. CareStart RDT is an immunochromatographic test coated with monoclonal antibodies in two separate bands, one recognizing the specific histidine-rich protein-2 (HRP-2) associated with the presence of Plasmodium falciparum and the other detecting presence of pan malaria-specific antigen (pLDH) of all malarial parasites species. The real-time PCR assay, known as photo-induced electron transfer (PET)-PCR, was also performed.

The investigators reported that when considering PCR as the gold standard, CareStart RDT showed high sensitivity (97.3%) and specificity (94.1%) with a positive predictive value (PPV) and negative predictive value (NPV) of 97.3% and 94.1%, respectively. Microscopy had a sensitivity of 93.2% and specificity of 100%, and PPV and NPV of 100% and 87.2%, respectively. CareStart RDT showed less false negative but more false positive results compared to microscopy.

The authors concluded that although RDT usefulness in low transmission areas or in the detection of low parasite density infections is being questioned, CareStart RDT showed good sensitivity comparable to that performed by expert microscopist. However, in the wake of reported HRP2 deletion in other countries, microscopy should always accompany the use of RDT. Combination of RDT and microscopy together with the evaluation of malaria RDTs over time should be a powerful tool for diagnosing malaria in endemic countries. The study was published on August 10, 2017, in the Malaria Journal.

Related Links:
Cheikh Anta Diop University


Platinum Member
ADAMTS-13 Protease Activity Test
ATS-13 Activity Assay
Verification Panels for Assay Development & QC
Seroconversion Panels
Complement 3 (C3) Test
GPP-100 C3 Kit
Gold Member
NEW PRODUCT : SILICONE WASHING MACHINE TRAY COVER WITH VICOLAB SILICONE NET VICOLAB®
REGISTRED 682.9
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Clinical Chemistry

view channel
Image: QIP-MS could predict and detect myeloma relapse earlier compared to currently used techniques (Photo courtesy of Adobe Stock)

Mass Spectrometry-Based Monitoring Technique to Predict and Identify Early Myeloma Relapse

Myeloma, a type of cancer that affects the bone marrow, is currently incurable, though many patients can live for over 10 years after diagnosis. However, around 1 in 5 individuals with myeloma have a high-risk... Read more

Immunology

view channel
Image: The cancer stem cell test can accurately choose more effective treatments (Photo courtesy of University of Cincinnati)

Stem Cell Test Predicts Treatment Outcome for Patients with Platinum-Resistant Ovarian Cancer

Epithelial ovarian cancer frequently responds to chemotherapy initially, but eventually, the tumor develops resistance to the therapy, leading to regrowth. This resistance is partially due to the activation... Read more

Technology

view channel
Image: Ziyang Wang and Shengxi Huang have developed a tool that enables precise insights into viral proteins and brain disease markers (Photo courtesy of Jeff Fitlow/Rice University)

Light Signature Algorithm to Enable Faster and More Precise Medical Diagnoses

Every material or molecule interacts with light in a unique way, creating a distinct pattern, much like a fingerprint. Optical spectroscopy, which involves shining a laser on a material and observing how... Read more

Industry

view channel
Image: The collaboration aims to leverage Oxford Nanopore\'s sequencing platform and Cepheid\'s GeneXpert system to advance the field of sequencing for infectious diseases (Photo courtesy of Cepheid)

Cepheid and Oxford Nanopore Technologies Partner on Advancing Automated Sequencing-Based Solutions

Cepheid (Sunnyvale, CA, USA), a leading molecular diagnostics company, and Oxford Nanopore Technologies (Oxford, UK), the company behind a new generation of sequencing-based molecular analysis technologies,... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.