Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
ZeptoMetrix an Antylia scientific company

MERIDIAN BIOSCIENCE

Meridian Bioscience manufactures, markets, and distributes diagnostic test kits, purified reagents and biopharmaceuti... read more Featured Products: More products

Download Mobile App




Clostridium Difficile Diagnostic Guidelines Updated

By LabMedica International staff writers
Posted on 08 Sep 2016
New guidelines on the best practice methods to diagnose Clostridium difficile infection (CDI) have been released and the latest document updates the original 2009, and includes recommendations concerning the use of new diagnostic technology such as nucleic acid amplification tests (NAAT).

The main objectives of this update of the guidance document are to summarize the currently available evidence concerning laboratory diagnosis of CDI and to formulate and revise recommendations to optimize CDI testing. More...
This update is essential to improve the diagnosis of CDI and to improve uniformity in CDI diagnosis for surveillance purposes among European countries.

Scientists working under the auspices of The European Society of Clinical Microbiology and Infectious Diseases (ESCMID, Basel, Switzerland) identified 795 new studies, of which 693 were excluded and 102 selected for review. Of these, a further 61 were excluded, leaving 41 studies to be taken forward and used to support the new guidelines. Reasons for exclusion included incorrect or inconsistent reference testing, incorrect or inconsistent index testing, incorrect sample storage and incomplete sample testing. A total of 43 studies were also considered from the original meta-analysis, of which 28 were excluded and 15 taken forward.

Various laboratory assays available from commercial suppliers were assessed for their ability to diagnose CDI accurately. A reference test, typically cell cytotoxicity neutralization assay (CNNA) or toxigenic culture (TC) was used to investigate the accuracy of several tests that have emerged since 2009. These included enzyme immunoassays (EIA) that detect glutamate dehydrogenase or toxins A and B, and the new NAATs.

The strongest recommendations based on the evidence from all studies in the meta-analysis were: Samples to be tested for CDI should not be limited to cases in which a physician has specifically recommended; a rectal swab can be used for testing by (toxigenic) culture, NAAT or glutamate dehydrogenase (GDH) EIA in patients with apparent ileus (inactive bowel with no discernable bowel sounds); single, standalone tests are not reliable and should not be used: a two-step algorithm is necessary.

This two-step algorithm involves a combination of fast assays with follow up tests: Route one – the two-stage procedure should begin with either an NAAT or GDH EIA test. Negative tests should be treated as CDI negative, while positive tests should be followed up with a toxin A/B EIA test to confirm the result. Route two – the two-stage procedure should begin with both the GDH EIA test and the toxin A/B EIA test. If both are positive, CDI is likely to be present. If both are negative, CDI is unlikely to be present, however if GDH is positive and toxin A/B is negative, then the tests may optionally be followed up with an NAAT or TC test.

E.J. Kuijper a professor of experimental microbiology and senior author of the study said, “The new guidelines are intended for use among medical microbiologists, gastroenterologists, infectious disease specialists and infection control practitioners. Our aim is to not only improve diagnosis of CDI, but also to standardize the diagnostic process across Europe to allow for improved surveillance of the disease.” The study was published online on July 22, 2016, in the journal Clinical Microbiology and Infection.

Related Links:
The European Society of Clinical Microbiology and Infectious Diseases


Platinum Member
Xylazine Immunoassay Test
Xylazine ELISA
Verification Panels for Assay Development & QC
Seroconversion Panels
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
Gold Member
Automatic Western Blot Analyzer
Tenfly Phoenix Blot Analyzer
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Clinical Chemistry

view channel
Image: QIP-MS could predict and detect myeloma relapse earlier compared to currently used techniques (Photo courtesy of Adobe Stock)

Mass Spectrometry-Based Monitoring Technique to Predict and Identify Early Myeloma Relapse

Myeloma, a type of cancer that affects the bone marrow, is currently incurable, though many patients can live for over 10 years after diagnosis. However, around 1 in 5 individuals with myeloma have a high-risk... Read more

Immunology

view channel
Image: The cancer stem cell test can accurately choose more effective treatments (Photo courtesy of University of Cincinnati)

Stem Cell Test Predicts Treatment Outcome for Patients with Platinum-Resistant Ovarian Cancer

Epithelial ovarian cancer frequently responds to chemotherapy initially, but eventually, the tumor develops resistance to the therapy, leading to regrowth. This resistance is partially due to the activation... Read more

Technology

view channel
Image: Ziyang Wang and Shengxi Huang have developed a tool that enables precise insights into viral proteins and brain disease markers (Photo courtesy of Jeff Fitlow/Rice University)

Light Signature Algorithm to Enable Faster and More Precise Medical Diagnoses

Every material or molecule interacts with light in a unique way, creating a distinct pattern, much like a fingerprint. Optical spectroscopy, which involves shining a laser on a material and observing how... Read more

Industry

view channel
Image: The collaboration aims to leverage Oxford Nanopore\'s sequencing platform and Cepheid\'s GeneXpert system to advance the field of sequencing for infectious diseases (Photo courtesy of Cepheid)

Cepheid and Oxford Nanopore Technologies Partner on Advancing Automated Sequencing-Based Solutions

Cepheid (Sunnyvale, CA, USA), a leading molecular diagnostics company, and Oxford Nanopore Technologies (Oxford, UK), the company behind a new generation of sequencing-based molecular analysis technologies,... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.