Evaluation of Rapid Rabies Tests Reveals Problems with Accuracy

By LabMedica International staff writers
Posted on 06 Jul 2016
If humans bitten by a rabid animal are treated quickly, the disease can usually be prevented but such post-exposure prophylaxis is expensive and should be reserved for bites from animals with confirmed infection, but testing dogs for rabies in resource-poor settings is challenging.

The gold standard for rabies diagnosis is the fluorescence antibody test (FAT), which requires that brain tissue is fixed on microscope slides, stained with fluorescently labelled antibodies, and examined under a fluorescence microscope. More...
Alternative diagnostics include various assays to detect virus, antigen or viral ribonucleic acid (RNA), the latter based on polymerase chain reaction (PCR) technology. All of these tests require laboratory equipment, trained staff, and temperature-sensitive reagents.

Scientists at the Friedrich-Loeffler-Institute (Greifswald-Insel Riems, Germany) and their international colleagues compared six commercial lateral flow devices (LFD) for the diagnosis of rabies and their analytical sensitivity. They examined the sensitivity of the tests, their ability to exclude rabies infection accurately, as well as their specificity, which reflects an accurate positive diagnosis, in comparison with fluorescent antibody tests (FAT) and PCR in over 100 samples from experimentally infected animals and animals infected in the wild.

The investigators found that while all six tests showed good specificity, that is none gave false positives, they found that none of them demonstrated good sensitivity across the different sample sets. In fact, more than half of all positive samples, those with positive FAT and PCR results yielded "false negative" LFD results. Some LFD tests did better than others, and in some cases specific batches of the same test did better than others, but overall the results were disappointing.

The Antigen Rapid Rabies Ag-Test (Bionote Inc, Hwaseong-si, South Korea) displayed a positive rate for seven samples; the Rabies Virus Ag Rapid Test (Green Springs, Shenzhen, China) for 10 samples; the Rapid Rabies Ag Test (Creative Diagnostics, Shirley, NY, USA) for 14 samples. The scientists did report that viral RNA can be stored and eventually extracted from the LFDs using standard procedures available at molecular diagnostic laboratories. In fact, they were able to detect viral RNA after six weeks of storage at room temperature.

The authors concluded that with their current limitations commercially available rabies LFDs cannot be recommended for routine diagnosis and surveillance. If animals were involved in a biting incident to a human being, they note that false negative results may induce the patient and the doctor to refrain from appropriate post-exposure prophylaxis (PEP) given its high cost, even if the leaflet accompanying the test states that results are to be confirmed by a reference method. The study was published on June 23, 2016, in the journal PLOS Neglected Tropical Diseases.

Related Links:
Friedrich-Loeffler-Institute
Bionote
Green Springs
Creative Diagnostics

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Verification Panels for Assay Development & QC
Seroconversion Panels
POCT Fluorescent Immunoassay Analyzer
FIA Go
Gold Member
Automatic Western Blot Analyzer
Tenfly Phoenix Blot Analyzer
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Clinical Chemistry

view channel
Image: QIP-MS could predict and detect myeloma relapse earlier compared to currently used techniques (Photo courtesy of Adobe Stock)

Mass Spectrometry-Based Monitoring Technique to Predict and Identify Early Myeloma Relapse

Myeloma, a type of cancer that affects the bone marrow, is currently incurable, though many patients can live for over 10 years after diagnosis. However, around 1 in 5 individuals with myeloma have a high-risk... Read more

Immunology

view channel
Image: The cancer stem cell test can accurately choose more effective treatments (Photo courtesy of University of Cincinnati)

Stem Cell Test Predicts Treatment Outcome for Patients with Platinum-Resistant Ovarian Cancer

Epithelial ovarian cancer frequently responds to chemotherapy initially, but eventually, the tumor develops resistance to the therapy, leading to regrowth. This resistance is partially due to the activation... Read more

Technology

view channel
Image: Ziyang Wang and Shengxi Huang have developed a tool that enables precise insights into viral proteins and brain disease markers (Photo courtesy of Jeff Fitlow/Rice University)

Light Signature Algorithm to Enable Faster and More Precise Medical Diagnoses

Every material or molecule interacts with light in a unique way, creating a distinct pattern, much like a fingerprint. Optical spectroscopy, which involves shining a laser on a material and observing how... Read more

Industry

view channel
Image: The collaboration aims to leverage Oxford Nanopore\'s sequencing platform and Cepheid\'s GeneXpert system to advance the field of sequencing for infectious diseases (Photo courtesy of Cepheid)

Cepheid and Oxford Nanopore Technologies Partner on Advancing Automated Sequencing-Based Solutions

Cepheid (Sunnyvale, CA, USA), a leading molecular diagnostics company, and Oxford Nanopore Technologies (Oxford, UK), the company behind a new generation of sequencing-based molecular analysis technologies,... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.