Posted on 15 Jul 2015
At present, diagnosis of Ebolavirus disease requires transport of venipuncture blood to field biocontainment laboratories for testing by real-time reverse transcription polymerase chain reaction (RT-PCR), resulting in delays that complicate patient care and infection control efforts.

However, RT-PCR is a slow and complex test that comes with attached risks for the health care workers responsible for the collection, transportation and testing of the blood. More...
The complexity and slow turnaround for this diagnostic have been blamed for delaying success in containing the Ebola epidemic.

An international team led by those at the Boston Children's Hospital (MA. USA) performed a rapid diagnostic test on fingerstick blood samples from 106 individuals with suspected Ebolavirus disease presenting at two clinical centers in Sierra Leone during February 2015. They compared the point-of-care rapid diagnostic test results with clinical real-time RT-PCR results (RealStar Filovirus Screen RT-PCR kit 1·0; altona Diagnostics GmbH; Hamburg, Germany) for venipuncture plasma samples tested in a Public Health England field reference laboratory.

The team also performed the rapid diagnostic ReEBOV Antigen Rapid Test (Corgenix; Broomfield, CO, USA), on whole blood and real-time RT-PCR on plasma, on 284 specimens in the reference laboratory, which were submitted to the laboratory for testing from many clinical sites in Sierra Leone. In point-of-care testing, all 28 patients who tested positive for Ebolavirus disease by RT-PCR were also positive by fingerstick rapid diagnostic test and 71 of 77 patients who tested negative by RT-PCR were also negative by the rapid diagnostic test. In laboratory testing, all 45 specimens that tested positive by RT-PCR were also positive by the rapid diagnostic test, and 214 of 232 specimens that tested negative by RT-PCR were also negative by the rapid diagnostic test.

The authors concluded that the ReEBOV rapid diagnostic test had 100% sensitivity and 92% specificity in both point-of-care and reference laboratory testing in this population. With two independent readers, the test detected all patients who were positive for Ebolavirus by altona real-time RT-PCR; however, this benchmark itself had imperfect sensitivity. The study was published on June 26, 2015, in the journal the Lancet.

Related Links:

Boston Children's Hospital 
altona Diagnostics GmbH
Corgenix 



Platinum Member
Xylazine Immunoassay Test
Xylazine ELISA
Verification Panels for Assay Development & QC
Seroconversion Panels
Complement 3 (C3) Test
GPP-100 C3 Kit
Gold Member
D-Dimer Test
Epithod 616 D-Dimer Kit
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Clinical Chemistry

view channel
Image: QIP-MS could predict and detect myeloma relapse earlier compared to currently used techniques (Photo courtesy of Adobe Stock)

Mass Spectrometry-Based Monitoring Technique to Predict and Identify Early Myeloma Relapse

Myeloma, a type of cancer that affects the bone marrow, is currently incurable, though many patients can live for over 10 years after diagnosis. However, around 1 in 5 individuals with myeloma have a high-risk... Read more

Immunology

view channel
Image: The cancer stem cell test can accurately choose more effective treatments (Photo courtesy of University of Cincinnati)

Stem Cell Test Predicts Treatment Outcome for Patients with Platinum-Resistant Ovarian Cancer

Epithelial ovarian cancer frequently responds to chemotherapy initially, but eventually, the tumor develops resistance to the therapy, leading to regrowth. This resistance is partially due to the activation... Read more

Technology

view channel
Image: Ziyang Wang and Shengxi Huang have developed a tool that enables precise insights into viral proteins and brain disease markers (Photo courtesy of Jeff Fitlow/Rice University)

Light Signature Algorithm to Enable Faster and More Precise Medical Diagnoses

Every material or molecule interacts with light in a unique way, creating a distinct pattern, much like a fingerprint. Optical spectroscopy, which involves shining a laser on a material and observing how... Read more

Industry

view channel
Image: The collaboration aims to leverage Oxford Nanopore\'s sequencing platform and Cepheid\'s GeneXpert system to advance the field of sequencing for infectious diseases (Photo courtesy of Cepheid)

Cepheid and Oxford Nanopore Technologies Partner on Advancing Automated Sequencing-Based Solutions

Cepheid (Sunnyvale, CA, USA), a leading molecular diagnostics company, and Oxford Nanopore Technologies (Oxford, UK), the company behind a new generation of sequencing-based molecular analysis technologies,... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.