Rapid Diagnostic Test for Drug Resistant Tuberculosis Reviewed

By LabMedica International staff writers
Posted on 17 Nov 2014
People suffering from a drug-resistant strain of Mycobacterium tuberculosis, the causative agent of tuberculosis (TB), are more likely to die from the disease, and require treatment with what are described as “second-line” drugs.

A rapid and accurate test that could identify people with resistant TB, including a type of TB that is resistant to almost all anti-TB drugs, called extensively drug-resistant tuberculosis (XDR-TB), is likely to improve patient care and reduce the spread of drug-resistant TB. More...


Scientists at the Liverpool School of Tropical Medicine (UK) have conducted an independent review to examine the diagnostic accuracy of a commercial assay for the detection of resistance to second-line anti-tuberculosis drugs. They reviewed the results from 21 studies, 14 of which reported the accuracy of the specific assay with direct testing, five of which looked at indirect testing, and two of which looked at both.

GenoType MTBDRsl (Hain Lifescience GmbH; Nehren, Germany) is the only rapid test that detects resistance to second-line fluoroquinolone (FQ) drugs and second-line injectable drugs (SLID) as well as detecting XDR-TB. MTBDRsl can be performed on TB bacteria grown from sputum, which is called indirect testing and can take a long time, or can be performed immediately on sputum, which is called direct testing.

By indirect testing, the test detected 83% of people with FQ resistance and rarely gave a positive result for people without resistance. In a population of 1,000 people, where 170 have FQ resistance, MTBDRsl correctly identified 141 people with FQ resistance and missed 29 people. Of the 830 people who do not have FQ resistance, the test correctly classified 811 people as not having FQ resistance and misclassified 19 people as having resistance. By direct testing, the test detected 85% of people with FQ resistance and rarely gave a positive result for people without resistance.

By indirect testing, the test detected 77% of people with SLID resistance and seldom gave a positive result for people without resistance. In a population of 1,000 people, where 230 have SLID resistance, MTBDRsl correctly identified 177 people with SLID resistance and missed 53 people. Of the 770 people who do not have SLID resistance, the test correctly classified 766 people as not having SLID resistance and misclassified four people as having resistance. By direct testing, the test detected 94% of people with SLID resistance and hardly ever gave a positive result for people without resistance.

By indirect testing, the test detected 71% of people with XDR-TB and rarely gave a positive result for people without XDR-TB. In a population of 1,000 people, where 80 have XDR-TB, MTBDRsl correctly identified 57 people with XDR-TB and missed 23 people. In this same population of 1,000 people, where 920 do not have XDR-TB, the test correctly classified 909 people as not having XDR-TB and misclassified 11 people as having XDR-TB.

Grant Theron, PhD, the lead author of the review, said, “Our review shows that in adults with TB, a positive result for second-line drugs, either fluoroquinolone or injectable, or XDR-TB can be treated with confidence. However, given that a number of people tested negative while having a resistant strain, clinicians may still want to carry out conventional testing in some cases.” The study was published on October 30, 2014, in the Cochrane Review.

Related Links:

Liverpool School of Tropical Medicine
Hain Lifescience GmbH 



Platinum Member
Xylazine Immunoassay Test
Xylazine ELISA
Verification Panels for Assay Development & QC
Seroconversion Panels
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
Gold Member
High-Density Lipoprotein Containing Cholesterol Assay
HDL-c direct FS
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Clinical Chemistry

view channel
Image: QIP-MS could predict and detect myeloma relapse earlier compared to currently used techniques (Photo courtesy of Adobe Stock)

Mass Spectrometry-Based Monitoring Technique to Predict and Identify Early Myeloma Relapse

Myeloma, a type of cancer that affects the bone marrow, is currently incurable, though many patients can live for over 10 years after diagnosis. However, around 1 in 5 individuals with myeloma have a high-risk... Read more

Immunology

view channel
Image: The cancer stem cell test can accurately choose more effective treatments (Photo courtesy of University of Cincinnati)

Stem Cell Test Predicts Treatment Outcome for Patients with Platinum-Resistant Ovarian Cancer

Epithelial ovarian cancer frequently responds to chemotherapy initially, but eventually, the tumor develops resistance to the therapy, leading to regrowth. This resistance is partially due to the activation... Read more

Technology

view channel
Image: Ziyang Wang and Shengxi Huang have developed a tool that enables precise insights into viral proteins and brain disease markers (Photo courtesy of Jeff Fitlow/Rice University)

Light Signature Algorithm to Enable Faster and More Precise Medical Diagnoses

Every material or molecule interacts with light in a unique way, creating a distinct pattern, much like a fingerprint. Optical spectroscopy, which involves shining a laser on a material and observing how... Read more

Industry

view channel
Image: The collaboration aims to leverage Oxford Nanopore\'s sequencing platform and Cepheid\'s GeneXpert system to advance the field of sequencing for infectious diseases (Photo courtesy of Cepheid)

Cepheid and Oxford Nanopore Technologies Partner on Advancing Automated Sequencing-Based Solutions

Cepheid (Sunnyvale, CA, USA), a leading molecular diagnostics company, and Oxford Nanopore Technologies (Oxford, UK), the company behind a new generation of sequencing-based molecular analysis technologies,... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.