Rapid point-of-care pathogen detection remains a challenge, especially for Staphylococcus aureus detection in respiratory samples. More...


A rapid S. aureus–specific lateral flow immunochromatography (LFI) test has been developed using a specific monoclonal antibody to the S. aureus cell-wall peptidoglycan.

Scientists at King's College London (UK) used a LFI strip and modified the antigen target and capture/detection antibody to achieve greater sensitivity and specificity. They used an affinity-purified mouse monoclonal anti-S. aureus antibody that was raised specifically against S. aureus cell-wall peptidoglycan and conjugated with gold colloid. They used samples from six volunteers with severe asthma as well as spiked sputum and bronchial lavage specimens.

The LFI test was shown to be specific for S. aureus with no signal development for other Staphylococcal species or common respiratory pathogens. Evaluation of S. aureus isolates spiked into induced sputum and bronchoalveolar lavage samples derived from severe asthmatic patients showed a detection limit of 106 colony forming units (CFU)/mL for the LFI. The LFI test strips positively detected methicillin-sensitive S. aureus (MSSA), methicillin-resistant S. aureus (MRSA). The test was also shown to successfully detect S. aureus in one sample independently determined to be S. aureus positive by quantitative polymerase chain reaction.

The authors concluded that that an LFI detection limit of equal to or greater than 106 CFU/mL may be sufficiently sensitive to screen for preliminary information in a number of applications, but LFI tests with lower detection limits of less than 104 CFU/mL would be more clinically relevant. Further studies are currently ongoing to lower the detection limits of the LFI test and evaluate the robustness of the assay for a number of different applications. The ability of the LFI test to rapidly detect S. aureus in clinical respiratory samples suggests that it might be a useful platform for further development of point-of-care diagnostic applications. The study was published in the January 2013 edition of the journal Diagnostic Microbiology & Infectious Diseases.

Related Links:
King's College London



Platinum Member
ADAMTS-13 Protease Activity Test
ATS-13 Activity Assay
Verification Panels for Assay Development & QC
Seroconversion Panels
POCT Fluorescent Immunoassay Analyzer
FIA Go
Gold Member
hCG Whole Blood Pregnancy Test
VEDALAB hCG-CHECK-1
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Clinical Chemistry

view channel
Image: QIP-MS could predict and detect myeloma relapse earlier compared to currently used techniques (Photo courtesy of Adobe Stock)

Mass Spectrometry-Based Monitoring Technique to Predict and Identify Early Myeloma Relapse

Myeloma, a type of cancer that affects the bone marrow, is currently incurable, though many patients can live for over 10 years after diagnosis. However, around 1 in 5 individuals with myeloma have a high-risk... Read more

Immunology

view channel
Image: The cancer stem cell test can accurately choose more effective treatments (Photo courtesy of University of Cincinnati)

Stem Cell Test Predicts Treatment Outcome for Patients with Platinum-Resistant Ovarian Cancer

Epithelial ovarian cancer frequently responds to chemotherapy initially, but eventually, the tumor develops resistance to the therapy, leading to regrowth. This resistance is partially due to the activation... Read more

Technology

view channel
Image: Ziyang Wang and Shengxi Huang have developed a tool that enables precise insights into viral proteins and brain disease markers (Photo courtesy of Jeff Fitlow/Rice University)

Light Signature Algorithm to Enable Faster and More Precise Medical Diagnoses

Every material or molecule interacts with light in a unique way, creating a distinct pattern, much like a fingerprint. Optical spectroscopy, which involves shining a laser on a material and observing how... Read more

Industry

view channel
Image: The collaboration aims to leverage Oxford Nanopore\'s sequencing platform and Cepheid\'s GeneXpert system to advance the field of sequencing for infectious diseases (Photo courtesy of Cepheid)

Cepheid and Oxford Nanopore Technologies Partner on Advancing Automated Sequencing-Based Solutions

Cepheid (Sunnyvale, CA, USA), a leading molecular diagnostics company, and Oxford Nanopore Technologies (Oxford, UK), the company behind a new generation of sequencing-based molecular analysis technologies,... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.