We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
LGC Clinical Diagnostics

Download Mobile App




Immunoassay Approved for Detecting Dengue Fever Virus

By LabMedica International staff writers
Posted on 04 May 2011
An enzyme-linked immunosorbent assay (ELISA) is now available to test blood samples for the presence of antibodies to the dengue virus. More...


The ELISA test is designed for the qualitative detection of Immunoglobulin M (IgM) antibodies to dengue recombinant antigens (DENRA) in serum for the presumptive clinical laboratory diagnosis of dengue virus infection in patients with clinical symptoms consistent with dengue fever or dengue hemorrhagic fever.

The complete kit includes one 96 well strippable plate with all necessary reagents and controls. The ELISA is easy to use and accurate and performance was thoroughly evaluated in prospective studies and with clinically confirmed cases of dengue 1-4 serotypes. It was developed with a new generation of US Centers of Disease Control and Prevention (CDC; Atlanta, GA, USA), licensed recombinants expressed in mammalian cells. The accuracy was improved by monitoring background reactivity with Normal Cell Antigen and employs a simple, one-step ratio method of interpretation.

Diagnostic testing for dengue is complicated by the fact that an IgM antibody response to the dengue virus infection is not detectable until 3-5 days after the onset of fever, which can produce a negative test result even though a person has dengue. During this IgM negative window, the dengue virus is present in the bloodstream. The DENV Detect IgM Capture ELISA test is based on technology patented by the CDC and manufactured by Inbios Inc, (Seattle, WA, USA). This new test shows cross-reaction with other closely related viruses such as those that cause West Nile disease. However, in most patient testing situations found in the US, a positive test result in a patient with signs or symptoms consistent with dengue should be considered presumptive evidence of dengue.

This is the first in vitro assay for dengue, where the US Food and Drug Administration, (FDA; Silver Springs, MD, USA), reviewed data for the test via the "de novo" pathway, an alternative path to market for devices that are low to moderate risk and may not require premarket approval. Alberto Gutierrez, PhD, director of the Office of In Vitro Diagnostics Device Evaluation and Safety in FDA's Center for Devices and Radiological Health, said, "Cases of dengue fever or dengue hemorrhagic fever can be potentially fatal for people who do not recognize the symptoms. This test will now aid healthcare professionals in their effort to more effectively diagnose dengue."

Related Links:

US Centers of Disease Control and Prevention
Inbios Inc.
US Food and Drug Administration




Platinum Member
Xylazine Immunoassay Test
Xylazine ELISA
Verification Panels for Assay Development & QC
Seroconversion Panels
POCT Fluorescent Immunoassay Analyzer
FIA Go
Gold Member
COVID-19 Antigen Self-Test
Panbio COVID-19 Antigen Self-Test
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Clinical Chemistry

view channel
Image: QIP-MS could predict and detect myeloma relapse earlier compared to currently used techniques (Photo courtesy of Adobe Stock)

Mass Spectrometry-Based Monitoring Technique to Predict and Identify Early Myeloma Relapse

Myeloma, a type of cancer that affects the bone marrow, is currently incurable, though many patients can live for over 10 years after diagnosis. However, around 1 in 5 individuals with myeloma have a high-risk... Read more

Immunology

view channel
Image: The cancer stem cell test can accurately choose more effective treatments (Photo courtesy of University of Cincinnati)

Stem Cell Test Predicts Treatment Outcome for Patients with Platinum-Resistant Ovarian Cancer

Epithelial ovarian cancer frequently responds to chemotherapy initially, but eventually, the tumor develops resistance to the therapy, leading to regrowth. This resistance is partially due to the activation... Read more

Technology

view channel
Image: Ziyang Wang and Shengxi Huang have developed a tool that enables precise insights into viral proteins and brain disease markers (Photo courtesy of Jeff Fitlow/Rice University)

Light Signature Algorithm to Enable Faster and More Precise Medical Diagnoses

Every material or molecule interacts with light in a unique way, creating a distinct pattern, much like a fingerprint. Optical spectroscopy, which involves shining a laser on a material and observing how... Read more

Industry

view channel
Image: The collaboration aims to leverage Oxford Nanopore\'s sequencing platform and Cepheid\'s GeneXpert system to advance the field of sequencing for infectious diseases (Photo courtesy of Cepheid)

Cepheid and Oxford Nanopore Technologies Partner on Advancing Automated Sequencing-Based Solutions

Cepheid (Sunnyvale, CA, USA), a leading molecular diagnostics company, and Oxford Nanopore Technologies (Oxford, UK), the company behind a new generation of sequencing-based molecular analysis technologies,... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.