We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
INTEGRA BIOSCIENCES AG

Download Mobile App




Rapid Urine Test Evaluated for Helicobacter Pylori Infection

By LabMedica International staff writers
Posted on 26 Jun 2014
A rapid urine test based on enzyme-linked immunosorbent assay (ELISA) has been developed for the detection of anti-Helicobacter Pylori antibodies in urine.

Several methods to diagnose H. More...
pylori infection have been developed, among which the urea breath test (UBT) is currently regarded as the most accurate assay, but the UBT is still expensive and not widely available in many countries.

Scientists at the Ho Chi Minh City Medicine and Pharmacy University (Vietnam) working with Japanese colleagues, enrolled 200 patients undergoing upper gastrointestinal endoscopy from October 2012 to December 2012. Three biopsies were taken from each patient: two for histologic examination and one for the rapid urease test (RUT).

The biopsy for RUT was taken from the greater curvature of the corpus, about 2 cm above the atrophic border. This biopsy location has been reported to optimize the sensitivity of the PyloriTek RUT to detect H. pylori (Serim Research Co.; Elkhart, IN, USA). Urine samples were collected and were processed within one hour of collection for the detection of antibodies against H. pylori using the Rapirun Helicobacter pylori Antibody Stick (Otsuka Pharmaceutical Co., Ltd.; Tokyo, Japan). The test measures human immunoglobulin G (IgG) antibodies against H. pylori in urine using the principle of immunochromatography.

Of the 200 patients, 111 (55.5%) were diagnosed as being H. pylori positive. The sensitivity, specificity, and accuracy of the Rapirun Stick test were 84.7%, 89.9%, and 87.0%, respectively. There were 17 (8.5%) false-negative patients and 9 (4.5%) false-positive patients. Of the 24 patients with gastro-duodenal ulcer, 22 (91.7%) had H. pylori infection. However, 7 of 22 (31.8%) patients with reflux esophagitis also had the infection.

The authors demonstrated the usefulness of the Rapirun Stick test for the diagnosis of H. pylori infection in a Vietnamese population and the sensitivity, specificity, and accuracy of the Rapirun Stick test were high. In several patients, RUT and histologic examination produced false-negative or false-positive results, leading to the possible misdiagnosis of H. pylori infection. The study was published on May 7, 2014, in the World Journal of Gastroenterology.

Related Links:

Ho Chi Minh University of Medicine
Serim Research Co.
Otsuka Pharmaceutical Co.



Platinum Member
Xylazine Immunoassay Test
Xylazine ELISA
Verification Panels for Assay Development & QC
Seroconversion Panels
POCT Fluorescent Immunoassay Analyzer
FIA Go
Gold Member
Blood Glucose Reference Analyzer
Nova Primary
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Clinical Chemistry

view channel
Image: QIP-MS could predict and detect myeloma relapse earlier compared to currently used techniques (Photo courtesy of Adobe Stock)

Mass Spectrometry-Based Monitoring Technique to Predict and Identify Early Myeloma Relapse

Myeloma, a type of cancer that affects the bone marrow, is currently incurable, though many patients can live for over 10 years after diagnosis. However, around 1 in 5 individuals with myeloma have a high-risk... Read more

Immunology

view channel
Image: The cancer stem cell test can accurately choose more effective treatments (Photo courtesy of University of Cincinnati)

Stem Cell Test Predicts Treatment Outcome for Patients with Platinum-Resistant Ovarian Cancer

Epithelial ovarian cancer frequently responds to chemotherapy initially, but eventually, the tumor develops resistance to the therapy, leading to regrowth. This resistance is partially due to the activation... Read more

Technology

view channel
Image: Ziyang Wang and Shengxi Huang have developed a tool that enables precise insights into viral proteins and brain disease markers (Photo courtesy of Jeff Fitlow/Rice University)

Light Signature Algorithm to Enable Faster and More Precise Medical Diagnoses

Every material or molecule interacts with light in a unique way, creating a distinct pattern, much like a fingerprint. Optical spectroscopy, which involves shining a laser on a material and observing how... Read more

Industry

view channel
Image: The collaboration aims to leverage Oxford Nanopore\'s sequencing platform and Cepheid\'s GeneXpert system to advance the field of sequencing for infectious diseases (Photo courtesy of Cepheid)

Cepheid and Oxford Nanopore Technologies Partner on Advancing Automated Sequencing-Based Solutions

Cepheid (Sunnyvale, CA, USA), a leading molecular diagnostics company, and Oxford Nanopore Technologies (Oxford, UK), the company behind a new generation of sequencing-based molecular analysis technologies,... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.