Capillary and Venous Blood Sampling Compared for Coagulation Assays

By LabMedica International staff writers
Posted on 17 Mar 2022
Print article
Image: The ACL-TOP 750 LAS coagulation analyzer (Photo courtesy of Werfen)
Image: The ACL-TOP 750 LAS coagulation analyzer (Photo courtesy of Werfen)

Clinical laboratories offer a wide range of coagulation assays used in the diagnosis and management of patients with hemostatic disorders, preoperative screening, or anticoagulation therapy monitoring.

The request from clinicians for capillary blood collection for other routine coagulation test, such as International Normalized Ratio, prothrombin time, activated partial thromboplastin time, and thrombin time, remains significant in particular from those involved in pediatrics. Capillary sampling offers a less invasive method for blood collection than venipuncture, which makes it more suitable for neonates, young children as well as for adult patients with poor venous access or severe anxieties concerning blood sampling.

Diagnostic Laboratorians at the University Medical Center Utrecht (Utrecht, The Netherlands) performed a method comparison between capillary and venous blood sampling for routine coagulation assays. Both venous and capillary (finger stick) blood samples were collected from 188 healthy volunteers and patients. In citrate plasma, International Normalized Ratio (INR), prothrombin time (PT), activated partial thromboplastin time (APTT), thrombin time (TT), fibrinogen, and D-dimer were measured according to routine protocols using the ACL-TOP 750 LAS (Werfen, Bedford, MA, USA) coagulation analyzer. Regression analysis was performed and the mean relative difference between capillary and venous sampling was reflected to the total allowable error.

The scientists reported that there was a strong correlations and acceptable variations, using the total allowable error (TEa) as decision limit, were found for INR, PT, TT, fibrinogen, and D-dimer between capillary and venous sampling, However, capillary sampling resulted in significant shorter APTT values when using the standard APTT-SP Liquid reagent with a mean bias of −10.4%.. The mean relative difference of TT and fibrinogen was −1.7% and −3.7%, respectively, but were considered acceptable variations using the TEa as a decision limit. D-dimer showed a mean relative difference of 1.2%], which fell within the range of acceptable variation.

The authors concluded that strong correlations and acceptable variations were found for INR, PT, TT, fibrinogen, and D-dimer between capillary and venous sampling. However, capillary sampling resulted in significantly shorter APTT values when using the standard APTT-SP Liquid reagent. Based on these results, capillary blood sampling proved to be an alternative blood withdrawal method for routine coagulation assays, with the exception of APTT, if a venipuncture is unavailable. The study was originally published online on February 3, 2022, in the journal Clinical Biochemistry.

Related Links:
University Medical Center Utrecht 
Werfen 

Platinum Member
Xylazine Immunoassay Test
Xylazine ELISA
Magnetic Bead Separation Modules
MAG and HEATMAG
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
Gold Member
Parainfluenza Virus Test
PARAINFLUENZA ELISA

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: Signs of multiple sclerosis show up in blood years before symptoms appear (Photo courtesy of vitstudio/Shutterstock)

Unique Autoantibody Signature to Help Diagnose Multiple Sclerosis Years before Symptom Onset

Autoimmune diseases such as multiple sclerosis (MS) are thought to occur partly due to unusual immune responses to common infections. Early MS symptoms, including dizziness, spasms, and fatigue, often... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: Microscope image showing human colorectal cancer tumor with Fusobacterium nucleatum stained in a red-purple color (Photo courtesy of Fred Hutch Cancer Center)

Mouth Bacteria Test Could Predict Colon Cancer Progression

Colon cancer, a relatively common but challenging disease to diagnose, requires confirmation through a colonoscopy or surgery. Recently, there has been a worrying increase in colon cancer rates among younger... Read more

Pathology

view channel
Image: A new study has identified patterns that predict ovarian cancer relapse (Photo courtesy of Cedars-Sinai)

Spatial Tissue Analysis Identifies Patterns Associated With Ovarian Cancer Relapse

High-grade serous ovarian carcinoma is the most lethal type of ovarian cancer, and it poses significant detection challenges. Typically, patients initially respond to surgery and chemotherapy, but the... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.