Point-of-Care Testing Evaluated for Early Coagulopathy Diagnosis

By LabMedica International staff writers
Posted on 09 Jun 2021
Print article
Image: The CoaguChek Pro II Coagulation Meter and CoaguChek PT Test Strips (Photo courtesy of Roche Diagnostics)
Image: The CoaguChek Pro II Coagulation Meter and CoaguChek PT Test Strips (Photo courtesy of Roche Diagnostics)
Hemorrhage and coagulopathy are particularly relevant complications and are often connected to injuries, surgical interventions, serious diseases, anticoagulant medication or pregnancy/delivery. Acute bleeding requires fast and targeted therapy and therefore, knowledge of the patient's potential to form a clot is crucial.

Treating bleeding complications, rapid hemostatic optimization (interventional, surgical, mechanical or medication) and targeted therapy are therapeutic goals and are therefore equivalent to those of coagulopathy treatment. The earlier a coagulopathy is diagnosed, the earlier a targeted therapy can be initiated. The international normalized ratio (INR) value is of particular importance for the diagnosis and therapy of coagulopathy.

Intensive Care Physicians at the University Hospital Frankfurt (Frankfurt, Germany) and their colleagues included in a study, one group that included hemorrhagic patients from the department of obstetrics (obstetric group = OG), and another group comprising patients admitted to the emergency department (emergency group = EG). The primary outcome measure was the difference between two INR results of one blood sample determined by point-of-care testing (POCT) and standard laboratory testing (SL).

After blood sampling, a drop of blood was applied immediately to the test stripe of the POCT device, CoaguChek Pro II (Roche Diagnostics GmbH, Mannheim, Germany). The CoaguChek Pro II is a portable device requiring an 8-μl sample volume. It measures the international normalized ratio (INR) based on an electrochemical reaction. Samples for SL analysis were sent to the central laboratory via a pneumatic dispatch system (EG) or personal-based transport (OG) for automated analysis with an ACL TOP 700 Hemostasis testing System, (Werfen GmbH, Munich, Germany) in combination with PT Re Combiplastin 2G reagents.

The team reported that INR results between POCT and SLA showed a high and significant correlation. POCT results were reported significantly more quickly (EG: 1.1 versus 39.6 minutes; OG: 2.0 versus 75 minutes) and required less time for analysis (EG: 0.3 versus 24.0 minutes; OG: 0.5 versus 45.0 minutes) compared to SLA. The time for transportation with the pneumatic tube was significantly shorter (8.0 versus 18.5 minutes) than with the personal-based transport system. The estimated blood loss was between 800 mL and 1300 mL.

The authors concluded that strip-based test systems may be suitable methods for the emergency diagnosis of hemorrhagic patients because their measurement results are available significantly more quickly and seem to support the use of point-of-care INR-devices to rule out pathological INR-values in bleeding patients. The test strip-based methods can be used as diagnostic elements in hemotherapy algorithms to implement fast and targeted hemotherapy that can positively impact the clinical outcomes of patients. The study was published on May 23, 2021 in the journal Practical Laboratory Medicine.

Related Links:
University Hospital Frankfurt
Roche Diagnostics
Werfen


Platinum Member
ADAMTS-13 Protease Activity Test
ATS-13 Activity Assay
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
Gold Member
D-Dimer Test
Epithod 616 D-Dimer Kit

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: Signs of multiple sclerosis show up in blood years before symptoms appear (Photo courtesy of vitstudio/Shutterstock)

Unique Autoantibody Signature to Help Diagnose Multiple Sclerosis Years before Symptom Onset

Autoimmune diseases such as multiple sclerosis (MS) are thought to occur partly due to unusual immune responses to common infections. Early MS symptoms, including dizziness, spasms, and fatigue, often... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: Microscope image showing human colorectal cancer tumor with Fusobacterium nucleatum stained in a red-purple color (Photo courtesy of Fred Hutch Cancer Center)

Mouth Bacteria Test Could Predict Colon Cancer Progression

Colon cancer, a relatively common but challenging disease to diagnose, requires confirmation through a colonoscopy or surgery. Recently, there has been a worrying increase in colon cancer rates among younger... Read more

Pathology

view channel
Image: A new study has identified patterns that predict ovarian cancer relapse (Photo courtesy of Cedars-Sinai)

Spatial Tissue Analysis Identifies Patterns Associated With Ovarian Cancer Relapse

High-grade serous ovarian carcinoma is the most lethal type of ovarian cancer, and it poses significant detection challenges. Typically, patients initially respond to surgery and chemotherapy, but the... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.