Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
LGC Clinical Diagnostics

Download Mobile App





AACC Advises Against Using Coronavirus Test CT Values to Guide COVID-19 Patient Care

By LabMedica International staff writers
Posted on 09 Jul 2021
The American Association for Clinical Chemistry (AACC; Washington, DC, USA) has issued a public statement advising against the use of coronavirus test cycle threshold (Ct) values to guide COVID-19 treatment or public health efforts.

The medical community has become increasingly interested in the possibility of using coronavirus test Ct values to improve care for COVID-19 patients and overall management of the pandemic. More...
When a patient gets a standard coronavirus test - known as a qualitative PCR test -Ct values are generated as part of the testing process. These values typically have an inverse relationship with the amount of virus in a patient specimen, with low Ct values indicating a high amount of virus in a sample, and high Ct values indicating the reverse. Because of this, some research has suggested that Ct values could potentially identify patients who have high viral loads and are at increased risk for serious disease. Other findings have also indicated that Ct values could potentially identify patients who aren’t infectious (i.e. those with low viral loads), which could improve contact tracing and outbreak tracking efforts.

However, conclusive data supporting the use of Ct values are lacking. In spite of these studies, many others in the medical community have cautioned against the use of Ct values, arguing that these values have numerous shortcomings and can’t reliably predict disease severity or transmissibility. In order to bring clarity to this issue, AACC members have released a statement that details the limitations of Ct values and recommends against their use. The statement emphasizes that, even though Ct values correlate with the amount of virus in specific specimens, studies have not actually established a relationship between Ct values and a patient’s overall viral load or infectiousness.

There are also numerous factors aside from the amount of virus in a specimen that can impact the Ct values generated during coronavirus testing. AACC’s statement lists all of these factors, which include variables such as patient age, the test instruments used, and even whether or not a patient blows their nose before sample collection. Even with these limitations, though, AACC’s statement acknowledges that clinicians might still want access to Ct values in certain circumstances. If clinical laboratories decide to report Ct values to clinicians who request them, the association recommends that labs include a prominent comment with every report explaining that the use of Ct values to guide patient management is discouraged and why.

“Along with the vaccines, coronavirus testing continues to play a critical role in managing the COVID-19 pandemic around the world,” said AACC President Dr. David G. Grenache. “AACC’s experts have therefore put together this document to provide much-needed guidance on this particular area of coronavirus testing, and to ensure that coronavirus PCR tests continue to be used in a way that best serves patient and public health needs.”

Related Links:
AACC


Platinum Member
SARS-CoV-2 Reactive & Non-Reactive Controls
Qnostics SARS-CoV-2 Typing
Verification Panels for Assay Development & QC
Seroconversion Panels
Complement 3 (C3) Test
GPP-100 C3 Kit
Gold Member
COVID-19 TEST READER
COVID-19-CHECK-1 EASY READER+
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Clinical Chemistry

view channel
Image: QIP-MS could predict and detect myeloma relapse earlier compared to currently used techniques (Photo courtesy of Adobe Stock)

Mass Spectrometry-Based Monitoring Technique to Predict and Identify Early Myeloma Relapse

Myeloma, a type of cancer that affects the bone marrow, is currently incurable, though many patients can live for over 10 years after diagnosis. However, around 1 in 5 individuals with myeloma have a high-risk... Read more

Immunology

view channel
Image: The cancer stem cell test can accurately choose more effective treatments (Photo courtesy of University of Cincinnati)

Stem Cell Test Predicts Treatment Outcome for Patients with Platinum-Resistant Ovarian Cancer

Epithelial ovarian cancer frequently responds to chemotherapy initially, but eventually, the tumor develops resistance to the therapy, leading to regrowth. This resistance is partially due to the activation... Read more

Technology

view channel
Image: Ziyang Wang and Shengxi Huang have developed a tool that enables precise insights into viral proteins and brain disease markers (Photo courtesy of Jeff Fitlow/Rice University)

Light Signature Algorithm to Enable Faster and More Precise Medical Diagnoses

Every material or molecule interacts with light in a unique way, creating a distinct pattern, much like a fingerprint. Optical spectroscopy, which involves shining a laser on a material and observing how... Read more

Industry

view channel
Image: The collaboration aims to leverage Oxford Nanopore\'s sequencing platform and Cepheid\'s GeneXpert system to advance the field of sequencing for infectious diseases (Photo courtesy of Cepheid)

Cepheid and Oxford Nanopore Technologies Partner on Advancing Automated Sequencing-Based Solutions

Cepheid (Sunnyvale, CA, USA), a leading molecular diagnostics company, and Oxford Nanopore Technologies (Oxford, UK), the company behind a new generation of sequencing-based molecular analysis technologies,... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.