Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
LGC Clinical Diagnostics

Download Mobile App




Diagnostic Values of Serum STAT4 and sEng Analyzed in Preeclampsia

By LabMedica International staff writers
Posted on 06 Nov 2019
Preeclampsia is a pregnancy complication characterized by high blood pressure and signs of damage to another organ system, most often the liver and kidneys. More...
Preeclampsia usually begins after 20 weeks of pregnancy in women whose blood pressure had been normal.

Preeclampsia can cause serious complications such as cerebral edema, pulmonary edema, cerebral hemorrhage, heart failure, coagulopathy, liver rupture, placental abruption, fetal growth restriction, and fetal death. It is one of the main causes of increased perinatal mortality.

Medical laboratorians at the Ningbo Mingzhou Hospital (Ningbo, China) enrolled 54 pregnant women with preeclampsia from October 2017 to June 2018 and 28 matched healthy pregnant women were set as the control group. The preeclampsia patients were included following the criteria: (a) age 20‐40 years; (b) hypertension, proteinuria, and edema; and (c) singletons, all of which are terminated by cesarean section and are healthy in the past.

The purpose of the study was to detect the levels of signal transducer and activator of transcription 4 (STAT4) and soluble endoglin (sEng) in preeclampsia patients and analyze the diagnostic values of STAT4 and sEng in preeclampsia. The team used the testing method of sEng and STAT4 enzyme-linked immunosorbent assay (ELISA) kits (R&D Systems, Minneapolis, MN, USA). The related clinical indexes of the pregnant women in each group were detected, including the prothrombin time (PT), fibrinogen (Fib), 24‐hour urine protein, serum creatinine (SCr), and alanine transaminase (ALT) within a week before delivery. The relationship between serum STAT4 level and pregnant women in the mild and severe preeclampsia groups was also analyzed.

The scientists reported that compared with control, the prothrombin time in preeclampsia was significantly lower, while the mean arterial pressure, 24‐hour urine protein, serum creatinine, fibrinogen, and ALT were significantly higher. The circulating levels of STAT4 and sEng were significantly increased in the preeclampsia. The circulating levels of STAT4 were statistically significant difference: 0.340 ± 0.062, 0.637 ± 0.159, and 1.513 ± 0.182 ng/mL in the control group, mild preeclampsia group, and severe preeclampsia group. The circulating levels of sEng in serum were 8.982 ± 1.089, 11.421 ± 1.330, and 13.152 ± 1.735 ng/mL in the control group, mild preeclampsia group, and severe preeclampsia group, with statistically significant differences. The serum levels of STAT4 and sEng in preeclampsia were positively correlated.

The authors concluded that both STAT4 and sEng have diagnosis values for preeclampsia, but the sensitivity and specificity of STAT4 were better than sEng, suggesting STAT4 can be used as a novel serum marker for diagnosis of preeclampsia, and thus postponed the development of the disease. The study was published on October 19, 2019, in the Journal of Clinical Laboratory Analysis.

Related Links:
Ningbo Mingzhou Hospital
R&D Systems



Platinum Member
ADAMTS-13 Protease Activity Test
ATS-13 Activity Assay
Verification Panels for Assay Development & QC
Seroconversion Panels
Complement 3 (C3) Test
GPP-100 C3 Kit
Gold Member
Influenza Virus Test
NovaLisa Influenza Virus B IgM ELISA
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Immunology

view channel
Image: The cancer stem cell test can accurately choose more effective treatments (Photo courtesy of University of Cincinnati)

Stem Cell Test Predicts Treatment Outcome for Patients with Platinum-Resistant Ovarian Cancer

Epithelial ovarian cancer frequently responds to chemotherapy initially, but eventually, the tumor develops resistance to the therapy, leading to regrowth. This resistance is partially due to the activation... Read more

Technology

view channel
Image: Ziyang Wang and Shengxi Huang have developed a tool that enables precise insights into viral proteins and brain disease markers (Photo courtesy of Jeff Fitlow/Rice University)

Light Signature Algorithm to Enable Faster and More Precise Medical Diagnoses

Every material or molecule interacts with light in a unique way, creating a distinct pattern, much like a fingerprint. Optical spectroscopy, which involves shining a laser on a material and observing how... Read more

Industry

view channel
Image: The collaboration aims to leverage Oxford Nanopore\'s sequencing platform and Cepheid\'s GeneXpert system to advance the field of sequencing for infectious diseases (Photo courtesy of Cepheid)

Cepheid and Oxford Nanopore Technologies Partner on Advancing Automated Sequencing-Based Solutions

Cepheid (Sunnyvale, CA, USA), a leading molecular diagnostics company, and Oxford Nanopore Technologies (Oxford, UK), the company behind a new generation of sequencing-based molecular analysis technologies,... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.