We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
ZeptoMetrix an Antylia scientific company

TOSOH BIOSCIENCE

Tosoh Bioscience develops automated immunoassay and HPLC analyzers that provide testing for a broad menu of quality a... read more Featured Products: More products

Download Mobile App




Sickle Cell Trait Confounds Blood Sugar Readings

By LabMedica International staff writers
Posted on 23 Feb 2017
Sickle cell trait (SCT) is a genetic hemoglobin variant found in 8% to 10% of African-Americans and it occurs in people with one copy of the mutation because if they had two copies, that would result in sickle cell disease.

Hemoglobin A1c (HbA1c) is a common blood biomarker used to measure blood sugar over time, but it may not perform as accurately among African-Americans with sickle cell trait and could be leading to a systemic underestimation of blood sugar control among that population.

A team of scientists led by those at the Brown University School of Public Health performed a retrospective cohort study on data from two studies and the analytic sample included 4,620 participants (mean age, 52.3 ±11.8 years; 2,835 women (61.3%); 367 (7.9%) with SCT) with 9,062 concurrent measures of fasting glucose and HbA1c. More...
Analysis of the primary outcome was conducted using generalized estimating equations (GEE) to examine the association of SCT with HbA1c levels, controlling for fasting or 2-hour glucose measures.

Among all the patients included in the analysis, HbA1c readings came from either of two widely used, clinically accepted assays made by Tosoh Bioscience Inc. that rely on a process called high-performance liquid chromatography. In addition to those measures, the scientists also compared fasting and two-hour blood glucose and statistically controlled for demographic and medical factors, such as gender, age, body-mass index and whether diabetes had already been diagnosed and whether it was being treated.

The team found that using standard clinical HbA1c cutoffs resulted in identifying 40% fewer potential cases of prediabetes and 48% fewer potential cases of diabetes in people with SCT than in people without SCT. Meanwhile, when the scientists used other blood glucose measures as the diagnostic criteria, they found no significant difference in the likelihood of diabetes and prediabetes among patients with or without SCT. Current diagnostic thresholds for HbA1C are greater than 5.7% for prediabetes and greater than 6.5% for diabetes.

The authors of the study therefore recommend that practitioners following African-American patients whose HbA1c levels are within 0.3 percentage points of a diagnostic cutoff also consider using additional blood glucose measures. Gregory A.Wellenius, ScD, an associate professor of epidemiology and co-author of the study said, “The strengths of the study are that it's the largest sample size ever used, it's across two different studies with somewhat different populations, and it's a more thorough evaluation than prior studies.” The study was published on February 7, 2017, in the Journal of the American Medical Association (JAMA).


Platinum Member
ADAMTS-13 Protease Activity Test
ATS-13 Activity Assay
Verification Panels for Assay Development & QC
Seroconversion Panels
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
Gold Member
DNA Extraction Kit
MagMAX DNA Multi-Sample Ultra 2.0 Kit
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Immunology

view channel
Image: The cancer stem cell test can accurately choose more effective treatments (Photo courtesy of University of Cincinnati)

Stem Cell Test Predicts Treatment Outcome for Patients with Platinum-Resistant Ovarian Cancer

Epithelial ovarian cancer frequently responds to chemotherapy initially, but eventually, the tumor develops resistance to the therapy, leading to regrowth. This resistance is partially due to the activation... Read more

Technology

view channel
Image: Ziyang Wang and Shengxi Huang have developed a tool that enables precise insights into viral proteins and brain disease markers (Photo courtesy of Jeff Fitlow/Rice University)

Light Signature Algorithm to Enable Faster and More Precise Medical Diagnoses

Every material or molecule interacts with light in a unique way, creating a distinct pattern, much like a fingerprint. Optical spectroscopy, which involves shining a laser on a material and observing how... Read more

Industry

view channel
Image: The collaboration aims to leverage Oxford Nanopore\'s sequencing platform and Cepheid\'s GeneXpert system to advance the field of sequencing for infectious diseases (Photo courtesy of Cepheid)

Cepheid and Oxford Nanopore Technologies Partner on Advancing Automated Sequencing-Based Solutions

Cepheid (Sunnyvale, CA, USA), a leading molecular diagnostics company, and Oxford Nanopore Technologies (Oxford, UK), the company behind a new generation of sequencing-based molecular analysis technologies,... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.