Blood Test Predicts Silent Heart Disease Risk

By LabMedica International staff writers
Posted on 19 Jan 2017
Coronary heart disease is the UK's single biggest killer, accounting for nearly 70,000 deaths in the UK each year. More...
When heart muscle is damaged it leaks a protein called troponin in to the blood stream. Patients suspected of suffering a heart attack will often be given a troponin test to aide diagnosis, but until now the test has not been used to assess future heart attack risk.

Cardiac troponin is an independent predictor of cardiovascular mortality in individuals without symptoms or signs of cardiovascular disease. The mechanisms for this association are uncertain, and a role for troponin testing in the prevention of coronary heart disease has yet to be established.

Scientists at the University of Edinburgh and their colleagues studied 6,595 men ages 45 to 64 years with moderate hypercholesterolemia (Low-density lipoprotein (LDL) cholesterol concentrations 152 to 228 mg/dL) and no prior history of myocardial infarction to receive placebo or pravastatin 40 mg/day. Plasma was obtained before randomization and at one year, and was stored at –80 °C. For the analysis, they identified all participants with sufficient stored plasma at both time points and as a result, 3,318 of the 6,595 study participants were included.

Cardiac troponin I concentrations in stored plasma were determined at baseline and at one year using the ARCHITECT STAT high-sensitive troponin I assay. The limit of detection is 1.2 ng/L, and the interassay coefficient of variation is less than 10% at 4.7 ng/L. The upper reference limit or 99th-centile value is 34 ng/L in men. All samples underwent centrifugation twice (3,000 relative centrifugal force for 10 minutes) to ensure samples were visibly homogeneous.

The team found that changes in blood levels of a high-sensitivity troponin test from Abbott Diagnostics accurately predicted the risk of a person suffering a heart attack or dying of coronary heart disease up to 15 years later. Troponin improved the prediction of coronary heart disease risk adding to traditional markers, such as cholesterol levels and blood pressure. If borne out in larger, more diverse, studies, doctors may be able to use the troponin test to determine which patients are most likely to develop coronary heart disease.

Those whose troponin levels decreased the most had a 5-fold lower risk of heart attack or death from coronary heart disease compared with those who troponin levels were unchanged or increased. A decrease in troponin could indicate statin treatment is effective, whereas any increases in blood troponin could prompt a change in treatment strategy. Nicholas L. Mills, MD, a professor of Cardiology and senior author of the study, said, “While blood cholesterol levels and blood pressure are important and associated with the risk of developing heart disease, troponin is a direct measure of injury to the heart. Troponin testing will help doctors to identify apparently healthy individuals who have silent heart disease so we can target preventative treatments to those who are likely to benefit most.” The study was published on December 19, 2016, in the Journal of the American College of Cardiology.


Platinum Member
ADAMTS-13 Protease Activity Test
ATS-13 Activity Assay
Verification Panels for Assay Development & QC
Seroconversion Panels
Complement 3 (C3) Test
GPP-100 C3 Kit
Gold Member
High-Density Lipoprotein Containing Cholesterol Assay
HDL-c direct FS
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Immunology

view channel
Image: The cancer stem cell test can accurately choose more effective treatments (Photo courtesy of University of Cincinnati)

Stem Cell Test Predicts Treatment Outcome for Patients with Platinum-Resistant Ovarian Cancer

Epithelial ovarian cancer frequently responds to chemotherapy initially, but eventually, the tumor develops resistance to the therapy, leading to regrowth. This resistance is partially due to the activation... Read more

Technology

view channel
Image: Ziyang Wang and Shengxi Huang have developed a tool that enables precise insights into viral proteins and brain disease markers (Photo courtesy of Jeff Fitlow/Rice University)

Light Signature Algorithm to Enable Faster and More Precise Medical Diagnoses

Every material or molecule interacts with light in a unique way, creating a distinct pattern, much like a fingerprint. Optical spectroscopy, which involves shining a laser on a material and observing how... Read more

Industry

view channel
Image: The collaboration aims to leverage Oxford Nanopore\'s sequencing platform and Cepheid\'s GeneXpert system to advance the field of sequencing for infectious diseases (Photo courtesy of Cepheid)

Cepheid and Oxford Nanopore Technologies Partner on Advancing Automated Sequencing-Based Solutions

Cepheid (Sunnyvale, CA, USA), a leading molecular diagnostics company, and Oxford Nanopore Technologies (Oxford, UK), the company behind a new generation of sequencing-based molecular analysis technologies,... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.