POC D-Dimer Assays Compared with Standard Method

By LabMedica International staff writers
Posted on 18 Apr 2012
D-dimer assays are effective for the exclusion of deep-vein thrombosis (DVT), but point-of-care (POC) D-dimer assays have only recently been fully evaluated.

Measurement of D-dimer has been enabled after the development of monoclonal antibodies used in enzyme-linked immunosorbent assays (ELISAs) which have a sensitivity of 98% with a negative predictive value of greater than 95%. More...


However, ELISAs are complicated, time-consuming, and labor intensive and could generally only be performed in laboratories during daytime working hours. Scientists at the Karolinska Institutet, (Stockholm, Sweden) compared five POC D-dimer assays with their routine Tinaquant fully automated quantitative immunoturbidimetric assay that utilizes microlatex particles coated with anti-human D-dimer monoclonal antibody. They tested 60 samples from patients with suspected DVT. The cut-off value was 0.25 µg/mL of D-dimer, which corresponds to 0.5 µg/mL of fibrinogen equivalent units (FEU).

The five POC assays tested were the Pathfast D-dimer chemiluminescent enzyme immunoassay (CLEIA) magnetic filtration (Mitsubishi Chemical; Tokyo, Japan); the Cardiac D-dimer sandwich method, using monoclonal gold-labeled antibodies which like the standard Tinaquant assay is from Roche Diagnostics, (Mannheim, Germany); the Vidas D-dimer, a sandwich method, using monoclonal antibodies with fluorescence detection (BioMérieux; Marcy l’Etoile, France); the Stratus CS D-dimer sandwich method using monoclonal antibodies radial partition (Siemens Diagnostics; Marburg, Germany); and the NycoCard D-dimer sandwich method, which uses monoclonal antibodies gold colloids (Nycomed Pharma; Oslo, Norway).

The results of the study showed that using 0.5 µg/mL as a cut-off value, four samples tested negative with Tinaquant were positive with Pathfast. There were no Tinaquant-positive samples tested negative with Pathfast, while the overall agreement was very good. Four samples were discrepant between Tinaquant and Cardiac with the lower cut-off of 0.4 µg/mL. Eight samples of 27 were negative with NycoCard although they were positive with the standard Tinaquant assay. The agreement with Tinaquant was excellent for both Vidas and Stratus.

The authors concluded that that the four of five tested POC D-dimer assays have an analytical profile comparable to that obtained using standard laboratory assay, while three of them may be used for rapid bed-side analysis. Their evaluation indicates that Pathfast D-dimer, Cardiac D-dimer and Stratus CS D-dimer can be used for rapid bed-side analysis and offers a possibility to adequately rule out DVT in outpatients within minutes after admission. The study was published on April 5, 2012, in the International Journal of Laboratory Hematology.

Related Links:

Karolinska Institutet
Mitsubishi Chemical
Roche Diagnostics




Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Verification Panels for Assay Development & QC
Seroconversion Panels
POCT Fluorescent Immunoassay Analyzer
FIA Go
Gold Member
Pipette Controller
Sapphire MaxiPette
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Immunology

view channel
Image: The cancer stem cell test can accurately choose more effective treatments (Photo courtesy of University of Cincinnati)

Stem Cell Test Predicts Treatment Outcome for Patients with Platinum-Resistant Ovarian Cancer

Epithelial ovarian cancer frequently responds to chemotherapy initially, but eventually, the tumor develops resistance to the therapy, leading to regrowth. This resistance is partially due to the activation... Read more

Technology

view channel
Image: Ziyang Wang and Shengxi Huang have developed a tool that enables precise insights into viral proteins and brain disease markers (Photo courtesy of Jeff Fitlow/Rice University)

Light Signature Algorithm to Enable Faster and More Precise Medical Diagnoses

Every material or molecule interacts with light in a unique way, creating a distinct pattern, much like a fingerprint. Optical spectroscopy, which involves shining a laser on a material and observing how... Read more

Industry

view channel
Image: The collaboration aims to leverage Oxford Nanopore\'s sequencing platform and Cepheid\'s GeneXpert system to advance the field of sequencing for infectious diseases (Photo courtesy of Cepheid)

Cepheid and Oxford Nanopore Technologies Partner on Advancing Automated Sequencing-Based Solutions

Cepheid (Sunnyvale, CA, USA), a leading molecular diagnostics company, and Oxford Nanopore Technologies (Oxford, UK), the company behind a new generation of sequencing-based molecular analysis technologies,... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.