Immunoassay Accurately Measures Serum Hepcidin-25

By LabMedica International staff writers
Posted on 08 Nov 2010
An enzyme linked immunoassay assay (ELISA) can precisely measure the concentration of hepcidin-25 in serum.

Hepcidin is a key regulator of iron metabolism deficiency has been linked to hemochromatosis and iron overload, while increased concentrations are found in anemia of malignancy and chronic diseases. More...


Hepcidin-23 is the active form of the protein that binds to the iron transporter ferroportin to cause its degradation. A sandwich ELISA test using two antihepcidin-25 monoclonal antibodies was compared with the liquid chromatography-mass spectrometry (LC-MS) method. One hundred serum samples from healthy volunteers (ages 18–64 years, mean age 37 years) with a broad ethnic range and an equal number of male and females, and 34 serum samples from cancer patients were tested at the Lilly Research Laboratories, (Eli Lilly and Company; Indianapolis, IN, USA).

The sandwich ELISA was highly specific for hepcidin-25, having a limit of quantification of 10 pg/mL. Serum concentrations of hepcidin-25 measured by ELISA correlated with hepcidin-25 concentrations measured by using an independent LC-MS assay. Hepcidin-25 concentrations were increased in 34 patients with cancer (median 54.8 µg/L, 25% - 75% range 23.2 - 93.5 µg/L,) and 76 with rheumatoid arthritis (median 10.6 µg/L, 25% - 75% range 5.9 - 18.4 µg/L,) compared with 100 healthy individuals (median 1.20 µg/L, 25% - 75% range 0.42 - 3.07 µg/L.

This sandwich ELISA could also be used to help diagnose iron deficiency anemia in difficult cases in which it may coexist with anemia of chronic disease. In uncomplicated iron deficiency, hepcidin concentrations would be expected to be quite low, whereas in anemia of chronic disease without coexisting iron deficiency, hepcidin concentrations would be expected to be increased. In patients with anemia of chronic disease, a relatively low serum hepcidin concentration might also indicate the presence of coexisting iron deficiency. The study was published in September 2010 in Clinical Chemistry.

Related Links:

Eli Lilly and Company




Platinum Member
Xylazine Immunoassay Test
Xylazine ELISA
Verification Panels for Assay Development & QC
Seroconversion Panels
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
Gold Member
Spinal Fluid Cell Count Control
Spinalscopics
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Immunology

view channel
Image: The cancer stem cell test can accurately choose more effective treatments (Photo courtesy of University of Cincinnati)

Stem Cell Test Predicts Treatment Outcome for Patients with Platinum-Resistant Ovarian Cancer

Epithelial ovarian cancer frequently responds to chemotherapy initially, but eventually, the tumor develops resistance to the therapy, leading to regrowth. This resistance is partially due to the activation... Read more

Technology

view channel
Image: Ziyang Wang and Shengxi Huang have developed a tool that enables precise insights into viral proteins and brain disease markers (Photo courtesy of Jeff Fitlow/Rice University)

Light Signature Algorithm to Enable Faster and More Precise Medical Diagnoses

Every material or molecule interacts with light in a unique way, creating a distinct pattern, much like a fingerprint. Optical spectroscopy, which involves shining a laser on a material and observing how... Read more

Industry

view channel
Image: The collaboration aims to leverage Oxford Nanopore\'s sequencing platform and Cepheid\'s GeneXpert system to advance the field of sequencing for infectious diseases (Photo courtesy of Cepheid)

Cepheid and Oxford Nanopore Technologies Partner on Advancing Automated Sequencing-Based Solutions

Cepheid (Sunnyvale, CA, USA), a leading molecular diagnostics company, and Oxford Nanopore Technologies (Oxford, UK), the company behind a new generation of sequencing-based molecular analysis technologies,... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.