We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
PURITAN MEDICAL

Download Mobile App




Nanoneedle Bio-patch Provides Minimally Invasive Drug Delivery

By LabMedica International staff writers
Posted on 20 Nov 2018
Print article
Image: Silicon nanoneedles embedded in a stretchable and translucent elastomer patch that can be worn on the skin to deliver exact doses of drugs directly into cells (Photo courtesy of Purdue University).
Image: Silicon nanoneedles embedded in a stretchable and translucent elastomer patch that can be worn on the skin to deliver exact doses of drugs directly into cells (Photo courtesy of Purdue University).
A flexible bio-patch made from silicon nanoneedles embedded in a thin layer of elastomer was shown to deliver exact doses of biomolecules to cells and tissues while minimizing discomfort to the wearer.

Vertically ordered arrays of silicon nanoneedles – due to their nanoscale dimension and low cytotoxicity – are capable of minimally invasive nanoinjection of biomolecules into living biological systems such as cells and tissues. Nanoneedle bio-patches are usually fabricated on a bulk silicon wafer that is able to withstand the high temperatures and corrosive chemicals employed in standard nanofabrication processes. These rigid, flat, and opaque silicon wafers do not conform favorably with the soft, curvilinear, and optically transparent biological systems for which they are intended.

To improve this situation, investigators at Purdue University (West Lafayette, IN, USA) developed a unique methodology that enabled construction of vertically ordered silicon nanoneedles on a thin layer of elastomer patch that could flexibly and transparently interface with biological systems.

The investigators reported in the November 9, 2018, online edition of the journal Science Advances that this methodology allowed the heterogeneous integration of vertically ordered silicon nanoneedles with a thin layer of elastomer patch, which could provide a certain degree of mechanical flexibility, optical transparency, and cell and tissue compatibility.

"This means that eight or nine silicon nanoneedles can be injected into a single cell without significantly damaging a cell. So we can use these nanoneedles to deliver biomolecules into cells or even tissues with minimal invasiveness," said senior author Dr. Chi Hwan Lee, assistant professor in of biomedical engineering at Purdue University. "This nanoneedle patch is not only flexible but also transparent, and therefore can also allow simultaneous real-time observation of the interaction between cells and nanoneedles."

Related Links:
Purdue University

Platinum Member
ADAMTS-13 Protease Activity Test
ATS-13 Activity Assay
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
Gold Member
Influenza Virus Test
NovaLisa Influenza Virus B IgM ELISA

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: Signs of multiple sclerosis show up in blood years before symptoms appear (Photo courtesy of vitstudio/Shutterstock)

Unique Autoantibody Signature to Help Diagnose Multiple Sclerosis Years before Symptom Onset

Autoimmune diseases such as multiple sclerosis (MS) are thought to occur partly due to unusual immune responses to common infections. Early MS symptoms, including dizziness, spasms, and fatigue, often... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: Microscope image showing human colorectal cancer tumor with Fusobacterium nucleatum stained in a red-purple color (Photo courtesy of Fred Hutch Cancer Center)

Mouth Bacteria Test Could Predict Colon Cancer Progression

Colon cancer, a relatively common but challenging disease to diagnose, requires confirmation through a colonoscopy or surgery. Recently, there has been a worrying increase in colon cancer rates among younger... Read more

Pathology

view channel
Image: A new study has identified patterns that predict ovarian cancer relapse (Photo courtesy of Cedars-Sinai)

Spatial Tissue Analysis Identifies Patterns Associated With Ovarian Cancer Relapse

High-grade serous ovarian carcinoma is the most lethal type of ovarian cancer, and it poses significant detection challenges. Typically, patients initially respond to surgery and chemotherapy, but the... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.